How to Prepare Fire Alarm System AutoCad Drawings

How to Prepare Fire Alarm System AutoCad Drawings

Date : 2022-11-23

Whether you are installing a fire alarm system in a new or existing building, you will need to make sure the design and installation conforms to all state and local codes. A fire alarm system can be used to monitor other systems, but it is also used to detect and warn of fires. This article will discuss the steps you should take to make sure your installation conforms to code.

First, you need to create a plan. This drawing should have a floor plan that shows all areas of the building, the types of rooms and features that are included, and the placement of fire alarm devices. A floor plan is also a great way to show the installation company where to install equipment.

In addition to the floor plan, you will also need to provide shop drawings that depict the placement and wiring schematics of the fire alarm system installation drawings. These drawings also show where conventional devices are located to provide zone identification and to optimize system layout.

During the installation process, you will need to make sure all conductors are installed in raceways that are hot dip galvanized and that they are properly labeled. You will also need to ensure that all wiring meets NEC Article 760 A and C. You should also ensure that the cable in your panels is neatly tied.

In addition, you will need to prepare a record of completion that attests to the installation\'s compliance with the installation plan and to the testing performed in accordance with NFPA standards and the manufacturer\'s instructions. In some states, you will also need to provide an architect\'s signature.

After the installation, you will also need to make sure that the fire alarm equipment is clean and free of debris. This is to avoid any problems during future inspections or maintenance. You will also need to synchronize evacuation horns with the control panels. If you are installing an exterior horn and strobe, you will need to install these devices on the front of the building. You will also need to mount them in a fire alarm system installation drawing approved electrical box.

After all the work is completed, you will need to prepare a report for the local authorities. This report will contain all the necessary information to verify that the work was performed according to the specifications and the manufacturer\'s instructions.

You will also need to provide a hard copy of the fire alarm system installation drawing, which must show all system components and the wire routing. You must submit this to the Coordinator of Alarms, URI prior to the final fire alarm acceptance test.